The EESIFLO EASZ-12 Doppler Flow Switch
continuously measures the velocity of fluid in pipelines
using the non -intrusive Doppler principle. The switch is
quick and easy to install with no holes in the pipe, no
sensor fouling, no maintenance and no downtime for sensor
installation.
The EASZ-12 is designed for use with fluids, which contain
in excess of 0.1% suspended solids or bubbles, having a
size greater than 100 microns. Typical applications include
slurries, sewage, sludge, pulp, food products, aerated water
and abrasives. This versatile flow switch is suitable for
use on a variety of metal and plastic pipes.
The EASZ-12 includes a relay with adjustable high and low
setpoint control and adjustable delay-on and delay -off
timers. The EASZ-12 has two selectable flow ranges, 0 -
6.5 f/s and 0 - 19.6 f/s, with the flow rate indicated on
the 10 LED bar graph flow indicator.
 |
 |
| Measuring Range
|
0 to 6.5 f/s (1)
0 to 19.6 f/s (2) |
| Set Points |
0 to 100% of Range
|
| Timer Delays |
0 to 60 seconds
|
| Output |
1 Relay - 1Amp
SPDT |
| Transducer Cable
|
10ft length |
| Temperature |
Sensr -4 to 194
°F |
Electronics
Enclosure |
Electronics 14
to 122 °F
IP65 Polycarbonate
4.7 x 4.7 x 2.2 in |
|
|
| Power Input |
115/230V ac, 50Hz/60Hz
24V dc +/-10% |
| Transducer |
IP68 St/Steel
3.1 x 0.9 x 0.8 in |
| Indication LED's
|
10 LED bar graph
Range selection
Hi and Lo Alarm
Signal Strength |
| Failsafe Mode |
Selectable |
| Weight |
1.87lb |
|
| |