1
Fluids Types Any Homogeneous and Sonically Conductive Liquid
Temperature range -4 to 250 °F
Turbidity 10,000 mg/l or less recommended for optimum performance
2
Pipes Types Carbon steel, stainless steel, cast iron, plastic, copper, ductile, etc.
Diameter *Standard transducers = 2 to 40 inches
Small transducers for = 1/2 to 8 inches
Large transducers for = 12 to 196 inches
(For larger pipes please consult factory)
Lining Tar, Epoxy Resins, Metal, etc.
Minimum Straight pipe Upstream side = 10 X Pipe diameter
Downstream side = 5 X Pipe diameter
3
Measuring range Velocity -65 to +65 feet/second

4

Accuracy
Pipe Diameter
Flow Rate > 3 feet/sec
Flow Rate < 3 feet/sec
1/2 to 8 inch
2 to 40 inch
12 to 196 inch
±2.0%
±1.5%
±1.0%
±0.787 inches/sec
±0.591 inches/sec
±0.394 inches/sec
5
Measuring method Transit time
6
Output signal Analog output
Output items
Single output format
Dual output format

Instantaneous flow rate
4 ~ 20 mA DC (600 ohm or less, non-isolated) (selectable)
1 ~ 4 ~ 20 mA DC (600 ohm or less, non-isolated) (selectable)
Digital output
output items
output format
Measuring time, instantaneous/ rate, integrated contra-flow rate, error codes(selectable)
Via RS232C interface
Printer output
output items
Measuring time, instantaneous/ rate, integrated contra-flow rate, error codes(selectable)
7
Display Content Instantaneous flow rate/instantaneous velocity 4 digits, integrated flow rate 6 digits, flow/contra-flow (trend graph), item setting and data set, self-diagnosis results.
Format 128 X 128 Dot matrix
8
Settings Method Interactive key input
Items Pipe data settings, analog output, digital output, etc.
9
Wall Thickness measurement Range
Setting range
0.06 to inches (steel)
1640 to 32,805 feet/sec
10
Speed of Sound Range Range 328 to 9842 feet/sec
11
Memory back up Built-in lithium battery, integrated flow rate data, measurement setting data, logging data and measured data for 5 years
12
Logging function Stores approx. 55,000 items (measuring time, instantaneous rate, integrated rate, integrated contra rate, error codes
13
Power Supply Power source 11~ 30 V DC
Battery 7.2 V DC (7.5 hours)
AC adapter output voltage
input voltage
12V DC @ 11 VA * Battery recharge time ~ 4 hours.
1. 100/120 VAC 50/60 Hz (selectable)
14
Power consumption Approx. 3 Watts (on battery)
Approx. 10 Watts (12 VDC include battery recharging)
15
Temperature range -15 ~ +125 °F
16
Humidity 90% RH or less (no condensation)
17
Weight Approx. 2.8 pounds (with battery)

Copyright 2002 EESIFLO