| This
page is printable and fits in 1 A4 paper. |
|
Should it be necessary to extend the cable, EESIFLOs
only recommend RG62U co-axial cable. The connection should
be SOLDERED and connected as below.
The transducer cable to RG62U cable
The red cable from the transducer is soldered to the single
conductor on the RG62U cable and the black and screen from
the transducer are connected to the screen of the RG62U co-axial
cable.
RG62U cable and input connection on the
instrument
The other end of the RG62U cable should be connected to the
transducer connection with the single conductor going to the
red marked terminal and the screen going to the SCR marked
terminal.
The extra length of cable should not exceed 250m. This distance
could be shorter if the cable is run close to high voltage
cables.
|
|