| Installing
the Flow Transducers onto the Pipes |
In the following steps we'll enter the Measuring Mode and
install the transducers onto the pipes
- On the Main Menu, using the 4 and 6 keys,
scroll to MEA (Measuring) then press ENTER
- Select Channel A to measure then press ENTER
- Below the Channel >A< a small dash (-)
or check mark (
)
will appear as follows:
CHANN:
MEASUR |
>A<
-
|
B
.
|
Y
.
|
Z
.
|
|
|
- if a dash (-) appears, this must be changed to
a check mark (
)
by using the 8 or 2 keys. The screen should
now appear as follows
CHANN:
MEASUR |
>A<

|
B
.
|
Y
.
|
Z
.
|
|
|
- Press ENTER when the check mark is displayed
below Channel A.
- When A: Reflection Mod no >YES< appears
press ENTER
- The next screen that appears will indicate how far apart
the Flow Transducers must be installed on the Outflow
Pipe. Note, the distance indicated on this screen suggests
millimeters, however, the distance is actually in INCHES!!!
(Note to code writers ... Fix Display !!)
- Refer to Page 5-5 for a discussion on REFLECTED
MODE.
- Following the recommendations found on pages 3-1
through 3-4 in the EESIFLO 6000 Series Operating
Instruction, locate an appropriate mounting spot for the
Transducer Pair on the OUTLET or DOWNSTREAM
side of your process.
- Apply Ultrasonic Couplant to the bottom of the
Transducers
- Install Transducers with arrows pointing in the
same direction, and in the direction of flow. Refer to
Pages 5-6 through 5-10 for Detailed Mounting
Instructions
- Ensure Transducers are correct distance apart by pressing
ENTER and reviewing the SIGNAL STRENGTH
as discussed on page 5-2
- A GREEN signal indicates you have sufficient
signal strength to begin measuring. A RED signal will
indicate you should re-check your transducer installation.
- A screen will appear that indicates the temperature
at each Temperature Sensor. Press ENTER
- A screen will appear that allows you to enter an offset
for T1 Press ENTER
- A screen will appear that allows you to enter an offset
for T2 Press ENTER
- The next screen that appears will indicate the Heat
Flow in the units of your choosing.
- Pressing the 9 key will change the upper line of the
display to present more information
- Pressing the 3 key will change the lower line of the
display to present more information.
- Once measurements are complete, press BRK 3 times
to shut the meter off.
|