This page is printable and fits in 1 A4 paper.

http://www.eesiflo.com            
Download Brochure
 
Page:
Page 1/3

Features

- Dual mode flowmeter, field mounted unit
   IP65

- Easy to install clamp-on sensors with no
   process interruption

- Non-invasive flow measurement of liquids,
   no pipeline disturbance, no pressure loss

- Suitable for all commonly used pipe materials
   with pipe diameters from 6 mm to 6.5 m

- 1 to 4 flow channels, optional heat quantity
   measurement


Description

Our range of non-invasive flowmeters utilises ultra-sonic technology for the accurate flow measure-ment of liquids in full pipes.

The wall mounted version has been designed for permanent installations throughout the plant for applications where a non-invasive method of flow measurement is of paramount importance.

The measurement of flow is based on the principle that sound waves are influenced by a flowing medium. Measurements are made by penetrating the pipe with ultrasound and subsequently time differences, frequency variations and phase shifts of the ultrasonic signals are evaluated. This measuring technique has no effect on the flowing liquid. There is no pressure loss in the pipe and no wear on components of the measuring device.

The ultrasonic sensors are clamped onto the outside of the pipe, thus eliminating the need to dismantle the pipework and interrupt the process. Our meter can be applied to any type of standard pipe carrying clean or dirty liquids.

 

Advantages

- Low installation effort and costs
- Measurement is independent of fluid conductivity and pressure
- No pressure loss, no possibility of leakage
- Retrospective installation for existing plants possible
- No cutting of pipes necessary, no interruption of process,
  no plant shut down
- No additional fittings for maintenance required
- Hygienic measurement, no risk of contamination, suitable for
  ultra clean liquids
- No contact with medium, no risk of corrosion when used with
  aggressive media
- Cost advantages when used with large diameter pipes, high
  pressure systems, etc.
- Low stocking costs, nearly all pipe sizes are covered with only
  2 types of sensors