Recharging and battery care
- The10P is supplied with 4 x 1.2V 650mAh AA size Ni-Cd
removable cells and a 110/230Vac battery charger.
-
Charge battery fully before first
use and thereafter recharge only when fully discharged.
The 10P will indicate an error message when battery
charge is low and automatically switch off.
-
The 110/230Vac battery charger supplied
as standard with the 10P is a 65mA constant current
charger. The 10P should be switched off during charging.
The charge time for the 650mAh cells supplied is 14-16
hours (maximum 20 hours). THE CELLS MUST NOT BE OVER
CHARGED. Under charging of the cells will reduce the
life and capacity of the cells.
Low power consumption
- The10P is designed for low power consumption allowing
over 10 hours operation before re-charging the battery.
The 10P features a Low Battery warning with automatic
power down.
Storage
- If the 10P is to be stored for an extended time period
the cells should be removed.
| Menu
System (10P Version 1.00) |
The 10P menu system is easy to use and designed for programming
simplicity.
With the 10P powered up the 10P will test the suitability
of the flow signal. If the signal is suitable the flow total
and flow rate are displayed, if not an error message is
displayed.
START PROGRAMMING - Press "MENU"
Units
Metric and English units of rate and total measurement are
available.
Press
until desired value is displayed and MENU to continue.
Pipe ID
The precise dimension of the pipe internal diameter (ID) at
the point of measurement must be entered.
Use the
button to locate the curser below the number to be changed
and press the
button until the desired value is displayed and MENU
to continue
Rate units
Press
until desired unit is displayed and MENU to continue.
|