The 3000 series is designed
to measure flow for process control, particularly
by monitoring pump station operation, bio-solids handling
(RAS, WAS, thickened sludge) and to measure flow of
liquid-based slurry and other industrial process streams.
Because it applies Doppler methodology, it requires
a sample with adequate suspended solids, particles,
or bubbles present.
The 3000 series is a clamp
on style flow meter that is non-intrusive to the flow
inside the pipe. This means that a customer can install
the 3000 series Flow Meter without interrupting the
flow.
The 3000 series has unique
Doppler sensing methods where readings are not possible
if there are insufficient Doppler reflective elements
in the conduit to prevent mis-application of its technology.
The 3000 series is a true microprocessor based Doppler
meter designed in a weatherproof enclosure and operates
on 110 or 240 VAC.
- Ease of Installation: The
single transducer assembly is non-intrusive and
clamps to the outside of the pipe, ideal for after
market /post construction installations. This permits
installation without flow interruption.
- Cost of Ownership: An economical
alternative to more expensive flow monitoring options
(magnetic, vortex) and is easy and economical to
maintain and service.
- Transducers sensors are
protected in a sealed steel housing and take seconds
to install: Simplified operation by a user friendly
keypad save time and money without the inconvenience
of cutting open pipes.
- Accuracy better than ±2%
of FS
- View Volumetric Flow Rate
and Total:
- Durable, keypad : Simplified
and uncluttered menu-driven programmability
- Microprocessor based circuit
- True Doppler that does not
allow user intervention by changing settings.
- Wet calibration performed
on each unit prior to shipment
EESIFLO 3000 series Flow
Meter Specifications:
General:
- Velocity Measurement: Ultrasonic
Doppler
- Velocity Range: 0.3 to 10
m/s (0.9 to 33 ft/s) 1
- Flow Accuracy: ±2%
of full Pipe Size, I.D.: 2 to 39in. (50mm to 1m)
- Pipe Material: Metal or
plastic
- Flow Rate Units: US, Metric,
Imperial
- Totalizer: Continuous
- Repeatability: 2% of reading
- Linearity: ±5% of
reading
- Damping Rate: Selectable
- Circuit : Microprocessor
based
- Display: 2 Line 16 Character
Instrument Enclosure:
- Dimensions: IP66 to EN 60529
- Material Al Si 12, DIN 1725.
Surface Treatment powder coating Protection: IP66,
NEMA 4X
- Instrument Weight: 10lbs
Transducers:
- Type: Non-invasive clamp-on
transducers
- Cable Length: (10m) user
can expand to 100 m /328 ft
- Protection: IP68
- Sensor Operating Temp.:
-4 to 194 °F
- Weight: 0.8lbs (350g)
Electrical:
- Supply Voltage: 115 or 230Vac
(or 9-30Vdc on request)
- Frequency Range: 50/60Hz
or dc
- Installation Category: II
- Pollution Degree: II
- Programming: Front Panel
membrane keypad
Set Points: 0 to 100% of Range
Output : 1 Relay - 1Amp SPDT, 4/20 mA active type
and Pulse
|